This section summarizes the changes and the additions that have been made to the options that define an Abaqus model.
| mod | (S) | *AMPLITUDE |
The SCALEY and SHIFTY parameters are no longer supported for amplitudes defined by user subroutines. | ||
| mod | (E) | *AQUA |
This option can now be used in Abaqus/Explicit to define the steady fluid field for submerged structures. | ||
| mod | (S) | *BEAM GENERAL SECTION |
Use the new LUMPED parameter to specify the mass matrix that will be used for linear Timoshenko beam elements in frequency extraction and modal analysis procedures. Use the new TAPER parameter to define linear section behavior of tapered cross-sections. | ||
| mod | (S) | *BEAM SECTION |
Use the new LUMPED parameter to specify the mass matrix that will be used for linear Timoshenko beam elements in frequency extraction and modal analysis procedures. Use the new TAPER parameter to define linear section behavior of tapered cross-sections. | ||
| mod | (E) | *CLOAD |
Load types TSB, TFD, TWD, and TSI are now available in Abaqus/Aqua working with Abaqus/Explicit. | ||
| mod | (E) | *CONTACT CONTROLS ASSIGNMENT |
The default value for the TYPE parameter is now ENHANCED EDGE TRACKING. | ||
| mod | (S) | *DAMAGE EVOLUTION |
Use the new FAILURE INDEX parameter to define the damage evolution laws corresponding to each failure mechanism specified in a user-defined damage initiation criterion for enriched elements. | ||
| mod | (S) | *DAMAGE INITIATION |
A new value is available for the CRITERION parameter. Set CRITERION=USER to specify a user-defined damage initiation criterion for enriched elements. Use the new FAILURE MECHANISMS parameter to define the total number of failure mechanisms to be specified in a user-defined damage initiation criterion. Use the new PROPERTIES parameter to define the number of material constants being specified for a user-defined damage initiation criterion. | ||
| mod | (S) | *DISTRIBUTION |
A distribution of membrane thickness can now be specified on the data lines. | ||
| mod | (E) | *DLOAD |
Load types PB, FDD, FDT, FD1, FD2, WDD, WD1, WD2, FI, FI1, and FI2 are now available in Abaqus/Aqua working with Abaqus/Explicit. | ||
| mod | (S)(E) | *DYNAMIC |
Use the new SINGULAR MASS parameter in Abaqus/Standard to control velocity and acceleration adjustments if a singular global mass matrix is detected during initialization or during contact impact/release computations. The “improved” element time estimation method in Abaqus/Explicit is now applied to three-dimensional continuum elements, in addition to elements with plane stress formulations. | ||
| mod | (E) | *DYNAMIC TEMPERATURE-DISPLACEMENT |
The “improved” element time estimation method is now applied to three-dimensional continuum elements, in addition to elements with plane stress formulations. | ||
| mod | (S)(E) | *ELEMENT OUTPUT |
Use the new EXTERIOR parameter for field output to define an element output set consisting of all the exterior elements in the model. | ||
| mod | (E) | *FLUID EXCHANGE |
Use the new CAVITY PRESSURE parameter to apply the fluid pressure on the fluid exchange surface or to model fluid exchange through a vent and apply the fluid pressure as an equivalent load on the perimeter of the surface. | ||
| mod | (S)(E) | *INITIAL CONDITIONS |
Use the new DRIVING ELSETS parameter to define the source region from where the temperatures are read from a previous analysis and the target region onto which the temperatures are mapped in the current analysis. | ||
| mod | (S) | *MEMBRANE SECTION |
Use the new MEMBRANE THICKNESS parameter to define membrane thicknesses using distributions. | ||
| mod | (S)(E) | *NODE OUTPUT |
Use the new EXTERIOR parameter for field output to define a node output set consisting of all the exterior nodes in the model. | ||
| mod | (S) | *RESPONSE SPECTRUM |
Two new values are available for the COMP parameter. Set COMP=R40 or R30 to use the 40% rule or 30% rule, respectively, for summing directional excitation components as recommended by the ASCE 4–98 standard. Two new values are available for the SUM parameter. Set SUM=DSC to use the double sum combination method. Set SUM=GRP to use the grouping method. | ||
| mod | (E) | *SECTION CONTROLS |
This option now allows the specification of a scale factor for the drill stiffness of shell elements in Abaqus/Explicit. For Eulerian EC3D8R elements, the pure viscous form of hourglass control is the default form and the integral viscoelastic form of hourglass control is not supported. | ||
| mod | (E) | *SHELL GENERAL SECTION |
This option now allows the specification of a distribution to define composite layer thickness for conventional shell elements in an Abaqus/Explicit analysis. | ||
| mod | (E) | *SHELL SECTION |
This option now allows the specification of a distribution to define composite layer thickness for conventional shell elements in an Abaqus/Explicit analysis. | ||
| mod | (S) | *SPECTRUM |
Use the new ABSOLUTE, AMPLITUDE, CREATE, DAMPING GENERATE, EVENT TYPE, FILE, RELATIVE, and TIME INCREMENT parameters to create a spectrum from a user-specified amplitude that describes a dynamic event. | ||
| mod | (S)(E) | *TEMPERATURE |
Use the new DRIVING ELSETS parameter to define the source region from where the temperatures are read from a previous analysis and the target region onto which the temperatures are mapped in the current analysis. | ||
| mod | (E) | *WAVE |
This option is now available in Abaqus/Explicit to define the wave field for submerged structures. Only fifth-order Stokes wave theory is available in Abaqus/Explicit. | ||
| mod | (E) | *WIND |
This option is now available in Abaqus/Explicit to define the wind field for submerged structures. |