Products: Abaqus/Standard Abaqus/CAE
Benefits: Removing semi-obsolete contact controls from the primary documentation and Abaqus/CAE dialog boxes enables users to focus on features that are more generally recommended.
Description: Several contact controls for Abaqus/Standard have been removed from Abaqus/CAE dialog boxes and are no longer documented in the Abaqus manuals. These controls remain available through the *CONTACT CONTROLS keyword option and the Abaqus Scripting Interface.
The following contact controls are affected:
Stabilization based on the initial contact opening distance.
Automatic calculation of contact separation and penetration tolerances.
Definition of a modified “hard” contact pressure-overclosure relationship, in which a certain number of nodes are allowed to violate contact conditions, including specification of
the number of nodes that can violate contact conditions,
an allowable overclosure distance before contact is enforced, and
an allowable “tensile” contact pressure before surfaces separate.
Delaying the onset of frictional constraints during changes in contact state.
Direct control over the use of Lagrange multipliers in enforcing contact constraints.