*CONTACT INITIALIZATION DATA
Define contact initialization methods for general contact.

This option is used to define contact initialization methods for Abaqus/Standard. The contact initialization method is applied to a contact interaction using the *CONTACT INITIALIZATION ASSIGNMENT option.

Product: Abaqus/Standard  

Type: Model data

Level: Model  

References:

Required parameter:

NAME

Set this parameter equal to a label that will be used to refer to this contact initialization method.

Optional parameters:

INTERFERENCE FIT

Include this parameter to treat initial overclosures as interference fits. If this parameter is omitted, initial overclosures will be resolved with strain-free adjustments.

MINIMUM DISTANCE

Set MINIMUM DISTANCE=YES (default) to automatically activate localized contact damping when nearby surfaces are touching at only a single point.

Set MINIMUM DISTANCE=NO to forgo this automatic localized damping.

SEARCH ABOVE

Set this parameter equal to a positive value to specify the maximum size of initial gaps between surfaces that are closed using strain-free adjustments. This parameter cannot be used with the INTERFERENCE FIT parameter.

SEARCH BELOW

Set this parameter equal to a positive value to specify a maximum overclosure tolerance; initial overclosures smaller than this tolerance are repositioned using strain-free adjustments or interference fits.

There are no data lines associated with this option.