*CO-SIMULATION CONTROLS
Specify the rendezvousing scheme for co-simulation.

This option is used to specify the rendezvousing scheme for co-simulation. It must be used in conjunction with the *CO-SIMULATION option to identify the analysis program for which the co-simulation controls are specified. This option is not required for co-simulation with MADYMO.

Products: Abaqus/Standard  Abaqus/Explicit  

Type: History data

Level: Step

References:

Required parameter:

NAME

Set this parameter equal to the label that will be used to identify the co-simulation controls. All co-simulation control names in the same input file must be unique.

Required parameter for co-simulation with MpCCI; optional parameter for co-simulation with Abaqus or AcuSolve: 

STEP SIZE

Set this parameter equal to a value that defines the constant coupling step size to be used throughout the coupled simulation.

Set STEP SIZE=IMPORT for Abaqus to import a coupling step size from the external program for the next coupling step. This setting is only valid when used with the *CO-SIMULATION, PROGRAM=MPCCI option.

Set STEP SIZE=EXPORT for Abaqus to export a coupling step size to the external program for the next coupling step. This setting is only valid when used with the *CO-SIMULATION, PROGRAM=MPCCI option.

When you specify PROGRAM=ACUSOLVE with the *CO-SIMULATION option and you do not specify the STEP SIZE parameter, the step size is computed automatically.

When you specify PROGRAM=ABAQUS with the *CO-SIMULATION option, you can specify the STEP SIZE parameter only in the Abaqus/Explicit analysis. If you do not specify the STEP SIZE parameter, the step size is computed automatically.

Optional parameters:

TIME INCREMENTATION

Set TIME INCREMENTATION=SUBCYCLE (default) to allow Abaqus to take one or more increments to reach the next target time to exchange data with the external program.

Set TIME INCREMENTATION=LOCKSTEP to force Abaqus to use only one increment to reach the next target time.

TIME MARKS

Set TIME MARKS=YES (default) to enforce the target time in an exact manner; that is, Abaqus will temporarily cut back the increment such that the exchange occurs at the specified target time.

Set TIME MARKS=NO to enforce the target time in a loose manner. This setting is applicable only when TIME INCREMENTATION=SUBCYCLE is used.

This parameter does not apply when using the *CO-SIMULATION, PROGRAM=ABAQUS option; the target time will always be enforced in an exact manner.

There are no data lines associated with this option.